Patient-specific Modelling of Blood-flow in Cerebral Aneurysms

D. Zajarias-Fainsod[1], M.J. Chappell[1], J.F. Collingwood[1], A. Rennie[2], S. Nagaraja[2], and A. Wilson[2]
[1]University of Warwick, Coventry, UK,
[2]University Hospital Coventry and Warwickshire NHS Trust, Coventry, UK

A first stage in this research was to determine the feasibility of patient-specific modelling and the use of in-silico techniques to study flow for the first time in the same vessels with and without an aneurysm. Three-dimensional renderings of the cerebral blood vessels were reconstructed from computed tomography angiograms of the head using MATLAB (The MathWorks) for image processing and ScanIP (Simpleware Inc.) for 3D rendering and meshing. Meshes were then imported into COMSOL Multiphysics for finite element analysis. Pulsatile blood-flow was simulated through the cerebrovascular vessels and the velocity, pressure and wall shear stress determined. This was done for both the vessels with the aneurysm and where the aneurysm had been ‘virtually’ removed. The results show a reduced shear stress on the vessel wall without the aneurysm which is consistent with the hypothesis that the wall is weakened and then subsequently balloons with the onset of hypertension.

Download