RF Module Release Notes

New Functionality in Version 4

Backward Compatibility vs Version 3.5a

Change in Dependent Variables

Version 4.0a has a comprehensive set of electromagnetic wave propagation formulations based on the electric field that covers all modeling situations.

However, it is no longer possible to solve for the magnetic field H as a dependent variable.

Models saved in version 3.5a that are based on an H formulation are translated to the new E formulation but need to be solved again to update the solution in version 4.0.

Far-Field Postprocessing

Far fields are not automatically read in when importing a 3.5a model into version 4.0a. The workaround is to manually add a Far Field Calculation node.

Pair Boundary Conditions

Pair boundary conditions are not yet implemented, except for some basic features.

This means that the assembly port boundary condition is not supported in version 4.0.